1 EPR available in CPAP and AutoSet modes
ResMed Therapy Modes and
Clinically Superior Algorithms
Technical Specifications
Pressure Ranges
CPAP
4–20 cm H
2
O (EPR 0-3)
AutoSet
APAP 4–20 cm H
2
O (EPR 0-3)
Bilevel (S, S/T, T, PAC)
EPAP 3–25 cm H
2
O, IPAP 4–30 cm H
2
O
VAuto
EPAP 4–25 cm H
2
O, IPAP 4–25 cm H
2
O
ASV and ASVAuto
EPAP 4–15 cm H
2
O,
Pressure Support 0–20 cm H
2
O
IVAPS
EPAP 3–25 cm H
2
O,
Pressure Support 0–27 cm H
2
O
Filter
Two-layered, powder-bonded,
polyester non-woven fiber
Altitude Compensation
Automatic
Electrical Requirements
100–240 V
DC Power
Direct connect cord
EasyCare Tx Software
Minimum Hardware and
Software Requirements
PC (Mac not supported)
Pentium 1 GHz CPU
1 GB RAM
1024 x 768 display resolution
10/100 Mbps Ethernet Port
Microsoft Windows Vista,
Windows XP ≥ SP2 or Windows 2007
Microsoft .NET Framework 2.0
Cat5 cable or available network port
between patient room and control room
S9 VPAP Tx Accessories
H5i
Cleanable Tub 36800
H5i Standard Tub 36803
ClimateLine
36995
ClimateLine
MAX
Oxy 36996
Filter (1 Pack) 36850
Filter (2 Pack) 36851
Filter (12 pack) 36852
Filter (50 pack) 36853
The S9 VPAP Tx puts access to all of our advanced titration modes at your
fingertips to provide complete care across the full range of sleep disorders.
ResMed technologies like iVAPS and ASVAuto our unique bilevel modes
combine with innovative features like TiControl
to make it easy and efficient
to achieve comfortable, quality patient care.
Adult and pediatric therapy titration applications like CPAP, VPAP S, ST, T and
PAC therapy modes are FDA cleared to treat patients weighing 30 lb (>13 kg)
and above regardless of age, allowing sleep labs to provide titration for a wider
range of patients including pediatrics.
• CPAP – Fixed pressure delivered with optional expiratory pressure relief (EPR
)
• AutoSet
– Automatically adjusts pressure in response to snore, flow limitation and
obstructive sleep apneas with no pressure support
• VPAP (Bilevel) – Delivers two treatment pressures one for inspiration (IPAP) and one
for expiration (EPAP) and provides control over the following bilevel therapy modes:
» S (Spontaneous) – Follows the natural breathing pattern, allowing patients to breathe
at their regular respiratory rate and rhythm
» S/T (Spontaneous/Timed) – Augments any breaths initiated by the patient,
but will also supply additional breaths if the breath rate falls below the clinician’s
set “backup” respiratory rate
» PAC (Pressure Assist Control) – The inspiration time is preset in the PAC mode.
There is no spontaneous/flow cycling. The inspiration can be triggered by the patient
when respiratory rate is above a preset value, or time-triggered breath will be delivered
at the backup breath rate.
» T (Timed) – The fixed respiratory rate and the fixed inspiration/expiration time set by
the clinician are supplied regardless of patient effort
» VAuto – Automatically adjusts pressure in response to flow limitation, snore and apneas;
pressure support (PS) is fixed throughout the night and can be set by the clinician
» Adaptive Servo-Ventilation (ASV and ASVAuto) – Treats the spectrum of central
breathing disorders, including mixed sleep apnea, complex sleep apnea (CompSA) and
periodic breathing such as Cheyne–Stokes respiration (CSR)
» iVAPS – Treats hypercapnic respiratory insufficiency, including obesity hypoventilation,
chronic obstructive pulmonary disease, neuromuscular disease and restrictive conditions
4 S9 VPAP Tx Lab System | Sleep Lab Titration Guide
ResMed.com